DataKinetics DSC110 User Manual page 121

Signalling converter
Table of Contents

Advertisement

7.20.2 Maintenance Blocking End
MNBLE
Maintenance Blocking End
This command ends the blocked condition of boards, links, voice resources,
remote data centres or circuits and brings them into service. The command
restores configuration data to the lower levels of the converter and brings the
timeslots into service. Possible grouping are:-
If the grouping being unblocked is already in the unblocked state then no action
is taken.
If a group is unblocked and it is circuit mapped to a Network Side group then the
Network Side group will clear it's partner hardware blocking.
N.B. If a RDC has previously been blocked but a file transfer was already in
progress subsequent MNBLE's using that RDC will fail with "NO SYSTEM
RESOURCES" until the file transfer is complete.
MNBLE:ASLINK=...;
Syntax
MNBLE:C7LINK=...;
MNBLE:CGRP=...;
MNBLE:BPOS=...;
MNBLE:RDC=...;
MNBLE:VRS=...;
DataKinetics DSC110 / DSC210 User Manual Issue 12
Access side signalling links.
SS7 signalling links.
Circuit groups.
Boards.
Remote Data Centres.
Voice Resources.
Page 121