DataKinetics DSC110 User Manual page 112

Signalling converter
Table of Contents

Advertisement

7.18.3 CCS SS7 Link Set End
C7LSE
CCS SS7 Link Set End
This command is used to end the SS7 linkset.
Syntax
C7LSE:LS=;
There should be no signalling links attached to the linkset.
Prerequisites
All configured SS7 links must be blocked.
There are no C7 Routes using this linkset.
Attributes
CONFIG
Example
C7LSE:LS=1;
7.18.4 CCS SS7 Link Set Print
C7LSP
CCS SS7 Link Set Print
This command obtains a print-out of the attributes for the SS7 linkset. If no link is
specified then the values for all linksets are shown.
Syntax
C7LSP:[LS=,];
Attributes
None
Example
C7LSP;
Output format
CCS SS7 Link Set
LS
OPC
DPC
1
1
3
2
2
4
EXECUTED
DataKinetics DSC110 / DSC210 User Manual Issue 12
LSSIZE SS7MODE
NI DUAL
2
ITU14
2
0
1
ANSI
2
0
Page 112