Measurements - DataKinetics DSC110 User Manual

Signalling converter
Table of Contents

Advertisement

7.21 Measurements

7.21.1 Measurements Circuit Group Print
MSCGP
Measurements Circuit Group Print
This command prints out traffic measurements for circuit groups.
The fields have the following meanings:-
CGRP
ICOFF
ICANS
OGOFF
OGANS
MAXDEV
ACCUM
PERIOD
If RESET=Y then the traffic measurement data will be reset.
Syntax
MSCGP:[CGRP=,][RESET=,];
Prerequisites
If specified the circuit group must be initiated.
If specified the circuit group must not be blocked.
Attributes
Example
MSCGP:CGRP=1;
MSCGP;
Circuit Group Traffic Measurements
CGRP ICOFF
ICANS
1
5000
4500
2
5432
5432
3
2400
2400
EXECUTED
DataKinetics DSC110 / DSC210 User Manual Issue 12
- Circuit Group.
- Number of incoming calls initiated
- Number of incoming calls answered.
- Number of outgoing calls initiated.
- Number of outgoing calls answered.
- Maximum number of devices busy at one time.
- Total accumulated call duration (hours) for calls in the group.
- Time since measurements on the group were last reset.
Specified in hours, minutes and seconds.
OGOFF
OGANS
MAXDEV ACCUM
6000
5500
24
6333
6333
30
0
0
6
PERIOD
5
01:00:00
6
01:00:00
1
01:00:00