7.11 Parameter Definitions

7.11.1 Parameter Table
The following table lists all parameters and details the possible values.
All numeric parameters are entered and output in decimal notation.
<text character> is either <lower case letter>, <upper case letter>, <digit>, $ , or
hyphen. The use of quotation marks to delimit text strings is not required.
NAME
DESCRIPTION
ALP
Sequential reference number of an
entry in the Alarm Log.
ANNOUNCE
Whether the announcement option is
available on the converter.
ANNC
Logical reference for an
announcement.
ASLINK
Logical reference for an Access side
signalling link.
ASTYPE
The Access Side signalling system
associated with a link.
Format xxxx-yy
xxxx = Access Side signalling system.
yy = Variant of Access Side signalling
system.
The following combinations are
currently supported:
Q931-x where x is a value between 0
and 13.
QSIG- x where x is a value between 0
and 13.
NI2 - x where x is a value between 0
and 13.
DPNSS- x where x is a value between
0 and 3
See Section 7.11.18 for a fuller
description of the Access Side variants.
BCIC
The circuit identification code of an
SS7 circuit that is the base CIC of a
circuit group.
BPOS
Board position number (for signalling
cards).
BRDTYPE
Board type descriptor,
format: xxx-y-z
xxx = board type
y = number of signalling processors on
the board
z = number of PCM ports on the board.
DataKinetics DSC110 / DSC210 User Manual Issue 12
RANGE
NOTES
1:9999
Y,N
Default = N
1:32
1:32
xxxx:
Q931,QSIG,NI2,
DPNSS
yy: 0:13
-31:4095
5:20
xxx – CS6
y – 0,2
z – 2:2