DataKinetics DSC110 User Manual page 72

Signalling converter
Table of Contents

Advertisement

7.11.18 Access Side Types
The possible settings for the Access Side type are:-
ASTYPE
Description
Variant
Q931-0
ETSI Q.931
Q931-1
ETSI Q.931 where Q931 acts as a transit network.
Q931-2
ETSI Q.931 and can be partner blocked
Q931-3
ETSI Q.931 where Q931 acts as a transit network and can be partner blocked.
Q931-10 to
Q931-10 to Q931-13 are reserved for proprietary use
Q931-13
QSIG-0
QSIG
QSIG -1
QSIG where QSIG acts as a transit network.
QSIG -2
QSIG and can be partner blocked
QSIG -3
QSIG where QSIG acts as a transit network and can be partner blocked.
QSIG -10 to
QSIG -10 to QSIG -13 are reserved for proprietary use
QSIG -13
NI2 -0
North American ISDN 2.
NI2 -1
ETSI Q.931 where NI2 acts as a transit network.
NI2 -2
ETSI Q.931 and can be partner blocked
NI2 -3
ETSI Q.931 where NI2 acts as a transit network and can be partner blocked.
NI2 -10 to
NI2 -10 to NI2 -13 are reserved for proprietary use
NI2 -13
DPNSS -0
Level 2 taken out of service whenever the circuits need to be blocked (PCM Loss or
partner blocking). Data call not supported.
DPNSS -1
Level 2 remains in service and calls are cleared whenever the circuits need to be
blocked (PCM Loss or partner blocking). Data call not supported..
DPNSS -2
Level 2 taken out of service whenever the circuits need to be blocked (PCM Loss or
partner blocking). Data calls supported.
DPNSS -3
Level 2 remains in service and calls are cleared whenever the circuits need to be
blocked (PCM Loss or partner blocking). Data calls supported.