7.18.12 CCS SS7 Signalling Link Print
C7SLP
CCS SS7 Signalling Link Print
This command is used to obtain a print-out of the attributes of SS7 Signalling
Link(s). If no link is specified, all initialised links are output.
Syntax
C7SLP:[C7LINK=...];
Attributes
None.
Example
C7SLP:C7LINK=1;
C7SLP;
Output format
Signalling Link Configuration
C7LINK EQU
TS
1
5-1
05-1-4
2
5-2
05-1-5
3
6-1
05-1-16 2
EXECUTED
DataKinetics DSC110 / DSC210 User Manual Issue 12
LS
SLC
M56K
PCR
1
4
0
N
1
6
0
N
2
1
N