DataKinetics DSC110 User Manual page 135

Signalling converter
Table of Contents

Advertisement

7.22.11 Remote Data Centre Periodic Report Initiate
RDPRI
Remote Data Centre Periodic Report Initiate
This command initiates a report collection period for which data is collected and
transferred over Ethernet to a Remote Data Centre (RDC).
Reports for circuit group and outgoing route traffic measurements can be specified.
The label is used as the directory name on the remote data centre the files are
written to.
The period is the interval between which data is collected, it will be rounded to the
nearest 5 minute interval.
Data can be added/deleted from the periodic report using the RDPDI/RDPDE
commands.
Prerequisites
The report has not already been initiated.
If specified RDC2 cannot have the same value as RDC1.
RDC1 must already have been initiated.
If specified RDC2 must already be initiated.
Limitations
Before transfer to a RDC can take place the directory, represented by the label,
must exist on the remote site.
Syntax
RDPRI:REPORT=,PRTYPE=,PERIOD=,LABEL=,RDC1=,[RESET=,][RDC2=,];
Attributes
CONFIG, RDC
Example
RDPRI:REPORT=1,PRTYPE=MSOGR,PERIOD=01:00:00,RDC1=1,
LABEL=ROUTES;
DataKinetics DSC110 / DSC210 User Manual Issue 12
Page 135

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsc210

Table of Contents