3. SPECIFICATION – DSC210

3.1 Electrical

3.1.1 Power supply
Voltage:
Power:
Current:
Fuse type:
3.1.2 PCM interface
Data rate:
Connector:
Pulse shape:
Framing:
3.1.3 Serial Ports
Connector:
Flow control:
Data bits:
Parity:
Stop Bits:
Baud rate:
3.1.4 Alarm Outputs
Type:
Designation:
Contacts:
Contact
rating:
Connector:
DataKinetics DSC110 / DSC210 User Manual Issue 12
46V to 56V DC (nominal 48V)
200W fully equipped
4 Amps maximum
8A HRC (located at rear of unit)
2048kbit/s
75 ohm BNC (unbalanced version)
120 ohm RJ45 (balanced version)
CCITT G.703
CCITT G.732
9-pin D-type male.
XON/XOFF.
7 or 8 user configurable.
Odd, Even or None, user
configurable.
1 or 2, user configurable
300, 600, 1200, 2400, 4800, 9600 or
19200 bits/s, user configurable.
Two relays which under normal (non-alarm)
conditions are energised. Upon detection of an
alarm condition or loss of power the relay
changes to the de-energised state.
Urgent and Prompt
Single, break before make changeover, voltage
free
60V DC 0.5 Amps
15-way D-type socket