DataKinetics DSC110 User Manual page 166

Signalling converter
Table of Contents

Advertisement

+5V fault
21
The internal +5 volt power rail is out of
range. This is usually due to either a faulty
power supply module or a faulty card
causing excessive current consumption.
+12V fault
22
The internal +12 volt power rail is out of
range. This is usually due to either a faulty
power supply module or a faulty card
causing excessive current consumption
-5V fault
23
The internal –5 volt power rail is out of
range. This is usually due to either a faulty
power supply module or a faulty card
causing excessive current consumption
-12V fault
24
The internal +12 volt power rail is out of
range. This is usually due to either a faulty
power supply module or a faulty card
causing excessive current consumption
ISUP maint ind
25
Diagnostic event relating to ISUP operation.
Persistent events of this type should be
reported to DataKinetics.
ISUP err ind
26
Diagnostic event relating to ISUP operation.
Persistent events of this type should be
reported to DataKinetics.
CNV event ind.
27
Diagnostic event relating to call control and
signalling conversion. Persistent events of
this type should be reported to DataKinetics.
CNV err ind
28
Diagnostic event relating to call control and
signalling conversion. Persistent events of
this type should be reported to DataKinetics.
AS CC err ind
29
Diagnostic event relating to Access Side call
control. Persistent events of this type should
be reported to DataKinetics.
AS BRD err ind
30
Diagnostic event relating to Access Side
signalling card. Persistent events of this type
should be reported to DataKinetics.
AS link fail
31
Loss of signalling on an Access Side
signalling link. Usually due to incorrect
configuration (signalling timeslot),
connectivity fault or inactive signalling
terminal at the remote end.
DataKinetics DSC110 / DSC210 User Manual Issue 12
0
0
0
0
0
0
0
0
CGRP
times 100
plus DEV
ASLINK
SYS
SYS
SYS
SYS
NONE
NONE
NONE
NONE
NONE
NONE
SIG
Page 166

Advertisement

Table of Contents
loading

This manual is also suitable for: