7.15.6 Circuit Assignment Device End
CADEE
Circuit Assignment Device End
This command is used to remove a device or CIC from a circuit group.
Syntax
CADEE:CGRP=,DEV=...;
CADEE:CGRP=,CIC=...;
Prerequisites
All devices or CICs specified must already have been assigned to the circuit group.
CICs cannot be specified for Access Side circuit groups.
The associated circuit group should be blocked.
The first device number + the base CIC number must not result in a negative
number.
If a CIC is initiated then it must not be less than the base CIC of the group or
greater than the groups base CIC + 31.
Attributes
CONFIG
Example
CADEE:CGRP=2,DEV=20
CADEE:CGRP=3,DEV=1&5;
7.15.7 Circuit Assignment Device Print
CADEP
Circuit Assignment Device Print
This command is used to list the devices that have been assigned to specific circuit
groups. For SS7 the base CIC is provided and the devices represent an offset from
the base CIC.
When listing by circuit group, only those devices assigned to that group are displayed.
Circuits within a circuit group that been assigned for signalling only operation are
marked with a 'S'. Circuits that carry voice or data are marked with a 'B' (Bearer).
Circuits not assigned to the group are marked with '-'.
Syntax
CADEP:[CGRP=];
Attributes
None.
Example
CADEP:CGRP=1;
CADEP;
Output format
Listing by CGRP:
Device Configuration
Device:
CGRP CIC
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
1
526
- B B B B B B B B B B B B B B B – B B B B B B B B B B B B B B B
2
- S – S S S – S – S S - - S - - - S S S – S S S S S S S S - - -
EXECUTED