7.16.32 Configuration Update Initiate
CNUPI
Configuration Update Initiate
This command is used to update configuration data or software on the converter.
The operation involves reading files containing either configuration data or software
from a remote data centre (if specified) or floppy disk and and loading it into
memory.
The file name given should file name of the file without the suffix. The suffix is
determined by the DTYPE. For example, the file CGV.CV1 for a DTYPE of LSC
would be entered as CGV.
The filename suffix for DTYPE=LSC is .CV1
The filename suffix for DTYPE=CCTAB is .MT1
The filename suffix for DTYPE=CONFIG is .CF1
For software update the filenames are fixed to those supplied by DataKinetics.
For software update from floppy disk the user will prompt for each disk in turn.
For software update from the RDC all software binaries must exist in the specified
directory on the RDC.
Note: During execution of this command there may not be a response from the
system for up to 3 minutes while the command is being executed.
Prerequisites
If the RDC is specified it should be initiated and not blocked.
If the DTYPE is SOFTWARE then no filename should be specified.
If the DTYPE is not SOFTWARE then a filename must be specified.
Syntax
CNUPI:DTYPE=,[RDC=,DIRECTORY=,][FILE=,];
Attributes
CLIAUTH,RDC,CONFIG
Example
CNUPI:RDC=1,DTYPE=LSC,DIRECTORY=AUTH,FILE=CGV;
DataKinetics DSC110 / DSC210 User Manual Issue 12