7.17.4 Custom Profile Called Number Print
CPCDP
Custom Profile Called Number Print
This command is used to obtain a print out of called party number profile(s). If no
outgoing route is specified then all combinations are output.
Syntax
CPCDP: [CPCD=];
Prerequisites
If specified, the called party number profile must already have been initiated.
Attributes
Example
CPCDP;
CPCDP:CPCD=3;
Output format
Custom Profile Called Number Configuration
CPCD CDNA CDNP LABEL
1
7
4
Intl
2
6
5
Unknown
EXECUTED
7.17.5 Custom Profile Calling Number Initiate
CPCGI
Custom Profile Calling Number Initiate
This command is used to initiate a calling party number custom profile The profile is
used on a point of origin or outgoing route basis to modify fields within the calling
party number prior to transmission in a signalling protocol message.
Syntax
CPCGI: CPCG=,[CGMX=,][CGNA=,][CGPR=,][CGNP=,][CG2NA=,][CG2PR=,]
Prerequisites
The calling party number custom profile has not already been initiated.
Attributes
CONFIG
Example
CPCGI:CPCG=16,CGNP=2,CGPR=1;
DataKinetics DSC110 / DSC210 User Manual Issue 12
[CG2NP=,][CGCB=,][LABEL=,];
Page 108