Maintenance - DataKinetics DSC110 User Manual

Signalling converter
Table of Contents

Advertisement

7.20 Maintenance

7.20.1 Maintenance Blocking Initiate
MNBLI
Maintenance Blocking Initiate
This command initiates blocking for boards, signalling links, voice resources,
remote data centres and groupings of both voice and signalling timeslots. A
blocking command will remove from use the board, voice resource, link or
timeslots covered by the command, it will also remove their configuration data
from the lower levels of the converter and only configuration management will
maintain knowledge of their existence. For voice circuits all calls will be
immediately released and no new calls will be allowed.
Possible grouping are:-
If the grouping being blocked is already in the blocked state then no action is
taken.
If a group is blocked and it is circuit mapped to a Network Side group then the
Network Side group will be made partner hardware blocked.
If a circuit group, voice resource, or C7 link has been inhibited the inhibiting will
be removed as part of the blocking action.
Syntax
MNBLI:ASLINK=...;
MNBLI:C7LINK=...;
MNBLI:CGRP=...;
MNBLI:BPOS=...;
MNBLI:RDC=...;
MNBLI:VRS=...;
Prerequisites
The item being blocked has been initiated.
When blocking a board all SS7 links, Voice Resources, Access Side links and
circuit groups on the board must already be blocked.
When blocking an Access Side Link all circuit groups on the link must already be
blocked.
If this is the last remote data centre to be blocked then it cannot be blocked until
all continuous records and periodic reports are ended.
Attributes
CONFIG,PROMPT
Example
MNBLI:ASLINK=12;
MNBLI:C7LINK=4;
Output format
Blocking ASLINK 1
Blocking ASLINK 2
EXECUTED
DataKinetics DSC110 / DSC210 User Manual Issue 12
Access side signalling links.
SS7 signalling links.
Circuit groups.
Boards.
Remote Data Centres.
Voice Resources.
Page 120

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsc210

Table of Contents