DataKinetics DSC110 User Manual page 124

Signalling converter
Table of Contents

Advertisement

7.20.4 Maintenance Inhibit End
MNINE
Syntax
Prerequisites
Attributes
Example
Output format
Uninhibiting CGRP 23
Uninhibiting CGRP 32
EXECUTED
DataKinetics DSC110 / DSC210 User Manual Issue 12
Maintenance Inhibit End
This command ends the inhibiting of a group of circuits or C7 links.
All circuits in the grouping are put in service and calls are allowed
(unless the circuits are also out of service for reasons other than inhibit).
The C7 link is activated and signalling is allowed to proceed.
The Voice Resource is activated and announcements can now be
played.
If a group is uninhibited and it is circuit mapped to a Network Side group
then the Network Side group will clear its partner maintenance blocking.
MNINE:CGRP=...;
MNINE:CGRP=,DEV=;
MNINE:CGRP=,CIC=;
MNINE:C7LINK=...;
MNINE:VRS=...;
Circuits in the circuit groups have been initiated and are inhibited.
The C7 links have been initiated and are inhibited.
CONFIG
MNINE:CGRP=23&&32;
MNINE:CGRP=1,DEV=5;
MNINE:CGRP=2,DEV=23;
MNINE:C7LINK=5;
Page 124