2. SPECIFICATION – DSC110

2.1 Electrical

2.1.1 Power supply (DC Version)
Voltage:
Power:
Current:
2.1.2 Power Supply (AC Version)
Voltage
Frequency
Power
2.1.3 PCM interface
Data rate:
Connector:
Pulse shape:
Framing:
2.1.4 Serial Port
Connector:
Flow control:
Data bits:
Parity:
Stop Bits:
Baud rate:
2.1.5 Alarm Outputs
Type:
Designation:
DataKinetics DSC110 / DSC210 User Manual Issue 12
46V to 56V DC (nominal 48V)
50W fully equipped
4 Amps maximum
Selectable:
100V-120V AC (nominal 110V)
200V-240V AC (nominal 220V)
50/60Hz
50W (fully equipped)
2048kbit/s
75 ohm BNC (unbalanced version)
120 ohm RJ45 (balanced version)
CCITT G.703
CCITT G.732
9-pin D-type male.
XON/XOFF.
7 or 8 user configurable.
Odd, Even or None, user configurable.
1 or 2, user configurable
300, 600, 1200, 2400, 4800, 9600 or
19200 bits/s, user configurable.
Two relays which under normal (non-
alarm) conditions are energised. Upon
detection of an alarm condition or loss
of power the relay changes to the de-
energised state.
Urgent and Prompt