DataKinetics DSC110 User Manual page 156

Signalling converter
Table of Contents

Advertisement

7.24.6 Status PCM Print
STPCP
Status PCM Print
This command requests a status report of the PCMs. The PCM status is one of the
following:-
(Note that some signalling software types currently support only Sync Loss and OK)
The Clock field is one of the following:-
Syntax
STPCP;
Prerequisites
None
Attributes
CONFIG
Example
STPCP;
Output format
PCM Status
PCM SYNCPRI PCM Status
5-1 1
PCM Loss
5-2 2
SYNC Loss
6-1 3
AIS
6-2 4
RAI
7-1 1
OK
7-2 1
OK
EXECUTED
DataKinetics DSC110 / DSC210 User Manual Issue 12
OK
- Normal operational state.
PCM Loss
- Loss of signal.
Sync Loss
- Loss of frame alignment.
RAI
- Remote alarm indication.
AIS
- Alarm indication signal.
OK
- The board is detecting a valid PCM signal which could potentially
be used for synchronisation.
Active - The board is detecting a valid PCM signal which is currently
providing synchronisation for the converter.
Not OK – The input to the board is not currently suitable for use as a
synchronisation source.
Fault
- A fault has been detected on the board which prevents it being
used as a synchronisation source.
Clock
Fault
Not OK
Not OK
OK
Active
OK
Page 156