Codabar

Usage:
Used in photo-finishing and library applications. Formerly used in some
medical applications but not typically used in newer applications.
Definition:
Codabar is a 16-character set (0 through 9, and the characters $, :, /, .,
+, and –) with start/stop codes and at least two distinctly different bar
widths.
Codabar Status
Serial Cmd:
<K471,status,start & stop match status,start & stop output,large inter-
character gap,fixed symbol length status,symbol length,check digit
type,check digit output status>
Default:
Disabled
Options:
0 = Disabled
Start & Stop Match Status (Codabar)
Usage:
Used to increase security of symbology.
Definition:
Requires the Codabar start and stop characters (a, b, c, or d) to match
before a valid read can occur.
Serial Cmd:
<K471,status,start & stop match
tus,large intercharacter gap,fixed symbol length status,symbol
length,check digit type,check digit output status>
Default:
Enabled
Options:
0 = Disabled
Start & Stop Output Status (Codabar)
Usage:
Used to verify matching.
Definition:
Causes the start and stop characters to be transmitted with symbol data.
Serial Cmd:
<K471,status,start & stop match
tus,large intercharacter gap,fixed symbol length status,symbol
length,check digit type,check digit status,check digit output status>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
status,start & stop output sta-
1 = Enabled
status,start & stop output sta-
1 = Enabled