Serial Verification
Usage:
These commands are useful in removing any doubt about the scanner's
acceptance and response to host configuration commands.
For example, if the current preamble is "SOM" and <Kd1, START> is
entered, the scanner will echo back <Kd1, SOM> since the attempted
entry "START" exceeds the four character limit for that command. There-
fore it is rejected and the existing "SOM" message is echoed back and
remains the preamble message.
Definition:
Allows the user to verify configuration command status.
Serial Command Echo Status
Important Note:
Definition:
When enabled, a configuration command
received from the host is echoed back to
the host with the resultant settings.
Function:
If a command with multiple fields is processed, some of the fields may
have been processed properly while others were not. The changes will
appear in the string echoed back so that the user will know which fields
did or did not change.
Serial Cmd:
<K701,serial command echo
trol/hex output>
Default:
Disabled
Options:
0 = Disabled
ESP will not function whenever this command is enabled.
1 = Enabled
Chapter 6 I/O Parameters
Host
status,serial command beep status,con-
MS-3 Laser Scanner User's Manual
Scanner
6-13
Need help?
Do you have a question about the MS-3 and is the answer not in the manual?
Questions and answers