Microscan MS-3 User Manual page 46

Laser scanner
Hide thumbs Also See for MS-3:
Table of Contents

Advertisement

RS-232/422 Host Port
Serial Cmd:
<K140,6,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>
Default:
No assignment
Options:
Any ASCII character except a null. Control characters can be used to
define RES through NAK in serial commands.
From Host
Definition:
This option allows the handshaking protocol to be initiated from the host,
if not configured in an unpolled mode. Messages sent to the host will
include the scanner's defined protocol. The status of From Host deter-
mines if messages sent from the host to the scanner must include the
defined protocol. If From Host is disabled, the defined protocol is not
included. If From Host is enabled, the defined protocol must be
included.
Serial Cmd:
<K140,6,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from
Default:
Disabled
Options:
0 = Disabled
MS-3 Laser Scanner User's Manual
3-8
1 = Enabled
host>