Chapter 6 I/O Parameters
Auto Frame: Auto Framing will be initiated when this button position is selected. To
abort auto-framing, press the test button once quickly. Auto framing is a background
routine that automatically adjusts the scan width to the length of a symbol. This proce-
dure can also be accessed in a terminal view by the <@> command.
Load New Master: This allows the button to function the same as the New Master Pin
command. The new master pin's consecutive decode requirement holds true for this but-
ton position when this mode is selected.
(See"New Master Pin" on page
7-9.)
Sleep Mode: If sleep mode is enabled, the test button will shut off the mirror motor
and laser. To exit sleep mode, press the test button once quickly.
MS-3 Laser Scanner User's Manual