Summary of Utilities Commands
Command Type
Read Rate
Counter Request
and Clear
<K224,
ter
symbols>
<K231,
number,data>
<Gmaster symbol num-
Matchcode
<K231,
<K231,
Part Number/
Checksum
<K500>
Device Control
<K501>
Table 11-2 Utilities Commands
Command
<Cp>
Enter Single Symbol Percent Rate Test
<C>
Enter Single Symbol Decode Rate Test
<J>
Exit Decode Rate and Percent Rate Test
<N>
Noread Counter
<O>
Noread Counter Reset
<T>
Trigger Counter
<U>
Trigger Counter Reset
<V>
Good Read/Match Counter
<W>
Good Read/Match Counter Reset
<X>
Mismatch Counter
<Y>
Mismatch Counter Reset
<E>
Enable Matchcode (see also <K223,...> on
<F>
Disable Matchcode (see also <K223,...> on
number of mas-
Set master symbol database size.
Also
<)data)>
Enter symbol data as master symbol #1.
master symbol
Enter symbol data to specified master symbol.
Also <Mmaster symbol number
<G>
Store next symbol scanned as master symbol #1.
Store next symbol scanned as specified master symbol.
ber>
<)>
Request master symbol #1.
Request all master symbol information.
<K231, ?>
Also
master symbol
Request specified master symbol information.
number?>
Also
master symbol
Delete specified master symbol.
number,>
Also <Mmaster symbol number
<))>
Delete Master Symbol # 1
<K225,status>
Enable/disable New master pin
<!>
Display Checksums of EPROM Flash memory
<!b>
Display Checksum for Boot Code
<!a>
Display Checksum for Application Code
<#>
Display Part Numbers
<#b>
Display Boot Code Part Number
<#a>
Display Application Code Part Number
<H>
Enable Laser Scanning
<I>
Disable Laser Scanning
or
<KE>
Motor On
or
<KF>
Motor Off
<L1>
Programmable Output 1
<L2>
Programmable Output 2
<L3>
Programmable Output 3
Name
<KM
number of master symbols>
<M?>
<M#?>
MS-3 Laser Scanner User's Manual
Chapter 11 Utilities
page
7-4.)
page
7-4.)
,
data>
,
>
11-3
Need help?
Do you have a question about the MS-3 and is the answer not in the manual?
Questions and answers