Symbol Data Output

Symbol Data Output

Usage:
Useful when the host needs symbol data only under certain conditions.
Definition:
Defines the conditions under which decoded symbols are transmitted to
the host.
Symbol Data Output Status
Serial Cmd:
<K705,symbol output
Default:
Good Read
Options:
0 = Disabled
1 = Match
Note: If set to Match or Mismatch, Symbol Output Status will not take effect unless
Matchcode Type is enabled and a master symbol is loaded into memory.
Disabled
Usage:
Useful when an application only needs to use the discrete outputs and
can allow the scanner to do the decision-making. When Disabled, the
host does not need the symbol data and the communication lines are
used only for setup and status checks.
Definition:
When set to Disabled, the scanner will not transmit any data that is gen-
erated during a read cycle (symbols, noreads, etc.).
Match
Usage:
Match is used in an application that requires specific symbol information
and needs to sort, route or verify based on matching the specific symbol
data.
Definition:
When set to Match, the scanner transmits symbol data whenever a sym-
bol matches a master symbol. However, if Matchcode Type is Disabled,
it transmits on any good read.
Note: A noread can still be transmitted if Enabled.
MS-3 Laser Scanner User's Manual
6-4
status,when to output>
2 = Mismatch
3 = Good Read