Read Cycle by ESP
Read Cycle by ESP
Click this Button to bring
up the
Read Cycle/
Triggering
menu
To change a setting,
double-click
the set-
ting and use your cur-
sor to scroll through
the options.
To open nested options,
single-click
the +.
Read Cycle by Serial Command
Command Title
Multisymbol
Trigger Mode
External Trigger State
Serial Trigger Character
Start Serial Trigger Character
End Serial Trigger Character
End of Read Cycle
Decodes Before Output
Automatic Gain Control
Scan Speed
Symbol Detect/Transition
Maximum Element
Scan Width Enhance
Laser Controls
MS-3 Laser Scanner User's Manual
4-2
<K222,
number of symbols,multisymbol separator>
<K200,
trigger mode,trigger filter duration>
<K202,
external trigger state>
<K201,
serial trigger character>
<K229,start trigger character>
<K230,
end trigger character>
<K220,
end of read cycle,read cycle timeout>
<K221,
number before output,decodes before output mode>
<K504,
gain level,AGC sampling mode,AGC min,AGC max>
<K500,scan speed>
<K505,
symbol detect status,transition counter>
<K502,
maximum element>
<K511,scan width enhance>
<K700,
laser on/off status,laser framing status,laser on position,laser
off position,laser power>
Format