Flows 59 062-322/062-393 Restart Printer
Version 2 2008.03.31
Checking the error
Turn off and on the power.
Does the error still occur when faxing?
Yes
Checking the connector connection
Reseat the connectors (P/J 1001 and
1002) on the PWBA CONT AIO.
Does the error still occur when faxing?
Yes
Replace the PWBA CONT AIO.
(Removal 24/Replacement 36)
No
No
1 - 124
Chapter 1 Troubleshooting
END
END