FIP-1. 27 Reached Limits 016-759
Step
Possible causative parts:
PWBA CONT AIO (PL10.6.6)
Check the [Dell ColorTrack] setting
1
Does the value of [User Registration] exceed the limitation?
Maximum user is 50.
2
Does the error still occur when printing?
Checking the PWBA CONT AIO installation
Reseat the PWBA CONT AIO. (Refer to Removal 24/
3
Replacement 36)
Does the error still occur when printing?
Version 2 2008.03.31
Check
1 - 255
Chapter 1 Troubleshooting
Remedy
Yes
Reset to 50 or less
Go to step 3.
and go to step 2.
Go to step 3.
End of work.
Replace the
PWBA CONT
End of work.
AIO.
No