Chapter 3 Removal and Replacement Procedures (RRPs)
Removal 24 KIT ESS PWBA (PL10.6.99)
Note: Use the wrist strap to protect the PWB from the electrostatic.
1) Remove the Tray 1. (Removal 1)
2) Open the COVER ASSY FRONT (PL10.2.1).
Note: Cover the drum of the PHD unit to avoid exposure to light.
3) Remove the PHD Unit. (Removal 3)
Note: The FUSER part is very hot. Take added care not to get burned when performing the
service operation.
4) Remove the FUSER ASSY. (Removal 9)
5) Remove the COVER ASSY SIDE R. (Removal 10)
6) Remove the COVER ASSY SIDE L. (Removal 14)
7) Remove the COVER POLE OUT. (Removal 15)
8) Remove the COVER ASSY ESS. (Removal 16)
9) Remove the COVER REAR. (Removal 17)
10) Remove the SHIELD ASSY ESS. (Removal 22)
11) Remove the PWBA FAX. (Removal 23)
12) Disengage all the connectors of the
PWBA CONT AIO (PL10.6.6).
3 - 45
Version 1
2008.02.01