FIP-1. 15 Replace Fuser Now 010-351/010-421

Step
Possible causative parts:
FUSER ASSY (PL6.1.1)
PWBA MCU (PL10.7.7)
Checking the life counter value of the FUSER ASSY
1
Does the life counter value show the near of the end?
Checking after reseating the FUSER ASSY
Reseat the FUSER ASSY.
Warning: Start the operation after the FUSER ASSY has
2
cooled down.
Does the error still occur when the power is turned OFF and
ON?
Checking after replacing the FUSER ASSY
Replace the FUSER ASSY. (Refer to Removal 9/
Replacement 51.)
Warning: Start the operation after the FUSER ASSY has
3
cooled down.
Does the error still occur when the power is turned OFF and
ON?
NOTE: After replacement, be sure to clear the life
counter value.
Version 1 2008.02.01
Check
1 - 241
Chapter 1 Troubleshooting
Remedy
Yes
Replace the
FUSER ASSY.
(Refer to Removal
9/ Replacement
Go to step 2.
51.) After
replacement, be
sure to clear the
life counter value.
Go to step 3.
End of work.
Replace the
PWBA MCU.
(Refer to Removal
End of work.
31/ Replacement
29.)