Step
Checking after reseating the PWBA HVPS
20
Reseat the PWBA HVPS.
Is the image printed correctly?
Checking after replacing the PHD UNIT
Replace the PHD UNIT. (Refer to Removal 3/Replacement
21
57.)
Is the image printed correctly?
Checking after replacing the PWBA CONT AIO
Replace the PWBA CONT AIO. (Refer to Removal 24/
22
Replacement 36.)
Is the image printed correctly?
Checking the ROS ASSY for connection
Check the connections between the ROS ASSY and PWBA
MCU.
Are P/J40, P/J 41, P/J411 and P/J 412 connected correctly?
23
24
Is the image printed correctly?
Checking after replacing the ROS ASSY
Replace the ROS ASSY. (Refer to Removal 44/
25
Replacement 16.)
Is the image printed correctly?
Version 2 2008.03.31
Check
1 - 376
Chapter 1 Troubleshooting
Remedy
Yes
End of work.
Go to step 21.
End of work.
Go to step 22.
End of work.
Go to step 23.
Reconnect the
connector(s) P/
J40, P/J41, P/J411
Go to step 25.
and/or P/J412
surely, then go to
step 24.
End of work.
Go to step 25.
Replace the
PWBA MCU.
End of work.
(Refer to Removal
31/ Replacement
29.)
No