Chapter 3 Removal and Replacement Procedures (RRPs)
Removal 50 PWBA HVPS (PL10.7.1)
Note: Use the wrist strap to protect the PWB from the electrostatic.
1) Remove the Tray 1. (Removal 1)
2) Open the COVER ASSY FRONT (PL10.2.1).
Note: Cover the drum of the PHD unit to avoid exposure to light.
3) Remove the PHD Unit. (Removal 3)
Note: The FUSER part is very hot. Take added care not to get burned when performing the
service operation.
4) Remove the FUSER ASSY. (Removal 9)
5) Remove the COVER ASSY SIDE R. (Removal 10)
6) Remove the COVER ASSY SIDE L. (Removal 14)
7) Remove the COVER POLE OUT. (Removal 15)
8) Remove the COVER ASSY ESS. (Removal 16)
9) Remove the COVER REAR. (Removal 17)
10) Remove the COVER TOP. (Removal 18)
11) Remove the SHIELD ASSY ESS. (Removal 22)
12) Remove the CHASSIS ASSY LVPS. (Removal 28)
13) Remove the COVER SCANNER LOW. (Removal 37)
14) Remove the COVER POLE IN. (Removal 38)
15) Remove the PLATE ASSY DUCT. (Removal 39)
16) Remove the CHASSIS ASSY BREAKER. (Removal 40)
17) Remove the COVER SIDE L LOW. (Removal 20)
18) Remove the KIT SHAFT PIVOT. (Removal 45)
19) Remove the COVER ASSY FRONT. (Removal 46)
20) Remove the KIT PIVOT. (Removal 47)
21) Remove the KIT TRANSFER & PIVOT. (Removal 48)
22) Remove the UPPER UNIT. (Removal 49)
23) Open the EDGING SADDLE
(PL10.5.6), removal the HARN ASSY
HVPS (PL10.8.5) from the PWBA HVPS
(PL10.7.1).