Protection Error 016-391 ..................................................................................................... 1 - Dell 2135cn Service Manual

Hide thumbs Also See for 2135cn:
Table of Contents

Advertisement

FIP-1. 21 Invalid ID 016-383 / Range Chk Error 016-384 / Header Error 016-385 / Check
Sum Error 016-386 / Format Error 016-387 / Open Flash Err. 016-388 / Protec-
tion Error 016-391
Step
Possible causative parts:
PWBA CONT AIO (PL10.6.6)
Checking the download file
1
Was the file for 2135c downloaded?
Checking the connection between PC and printer
Are your PC and the printer correctly connected by USB or
LAN?
2
Disconnect and reconnect the USB or network cable.
Does the error still occur when the power is turned OFF and
ON?
Checking after reseating the PWBA CONT AIO
Reseat the PWBA CONT AIO.
3
Does the error still occur when the power is turned OFF and
ON?
Checking re-downloading the correct file for 2135c
Re-download the correct file from Dell web site.
4
Does the error still occur when the power is turned OFF and
ON?
Version 2 2008.03.31
Check
1 - 249
Chapter 1 Troubleshooting
Remedy
Yes
Re-download the
Go to step 2.
correct file.
Go to step 3.
End of work.
Go to step 4.
End of work.
Replace the
PWBA CONT
End of work.
AIO. (Removal 24/
Replacement 36.)
No

Advertisement