FIP-1. 46 Codec Error 033-501 / Communication 033-763
Step
Possible causative parts:
PWBA CONT AIO (PL10.6.6)
IIT ASSY SUB (PL10.9.2)
Checking the error
1
Turn off and on the power.
Does the error still occur when faxing?
Checking the firmware
2
Click the [Updater] of the [Quick Launch Utility] on your PC.
Does the error still occur after uploading the firmware?
Checking the firmware
3
Click the [Updater] of the [Quick Launch Utility] on your PC.
Does the error still occur after uploading the firmware?
Checking the PWBA CONT AIO installation
Reseat the PWBA CONT AIO. (Removal 24/Replacement
4
36)
Does the error still occur when faxing?
Checking after replacing the PWBA CONT AIO
Replace the PWBA CONT AIO. (Removal 24/Replacement
5
36)
Does the error still occur when faxing?
Version 2 2008.03.31
Check
1 - 277
Chapter 1 Troubleshooting
Remedy
Yes
Go to step 2.
End of work.
Go to step 3.
End of work.
Go to step 4.
End of work.
Go to step 5.
End of work.
Replace the IIT
ASSY SUB.
End of work.
Removal 59/
Replacement 2)
No