EXHAUST PIPE BOLT AND MUFFLER BOLT

Tighten initially at 1 000 km (600 miles, 1 months) and
every 6 000 km (4 000 miles, 6 months) thereafter.
• Remove the under cover. (!7-14)
• Tighten the exhaust pipe bolts 1, exhaust pipe joint nuts 2
and muffler mounting nut 3 to the specified torque with a
torque wrench.
# Exhaust pipe bolt: 23 N·m (2.3 kgf-m, 16.5 lb-ft)
Exhaust pipe joint nut: 30 N·m (3.0 kgf-m, 21.5 lb-ft)
Muffler mounting nut: 23 N·m (2.3 kgf-m, 16.5 lb-ft)

VALVE CLEARANCE

Inspect initially at 1 000 km (600 miles, 1 months) and
every 6 000 km (4 000 miles, 6 months) thereafter.
• Remove the trunk box. (!7-18)
• Remove the air cleaner box and throttle body. (!5-14)
• Remove the cooling fan cover. (!3-11)
• Remove the cooling fan filter. (!3-11)
• Remove the cylinder head cover 1.
PERIODIC MAINTENANCE