Output voltage (Vcc voltage 4.5 – 5.0 V, ambient temp. 20 –
30 °C, 68 – 86 °F)
ALTITUDE
(Reference)
(ft)
(m)
0
0
2 000
610
2 001
611
5 000
1 524
5 001
1 524
8 000
2 438
8 001
2 439
10 000
3 048
ATMOSPHERIC
PRESSURE
(mmHg)
kPa
760
100
707
94
707
94
634
85
634
85
567
76
567
76
526
70
OUTPUT
VOLTAGE
(V)
3.4 – 3.6
3.2 – 3.4
2.9 – 3.2
2.7 – 2.9
FI SYSTEM