4-32
FI SYSTEM
Step 2
1) Turn the ignition switch OFF.
2) Measure the ECT sensor resistance.
$ ECT sensor resistance:
Approx. 1.14 kΩ Ω Ω Ω at 40 °C (104 °F) (Terminal – Terminal)
! 09900-25008: Multi circuit tester set
% Tester knob indication: Resistance (Ω Ω Ω Ω )
Refer to page 6-9 for details.
Is the resistance OK?
• Dg or B/Br wire open or shorted to ground, or
poor 4 or A connection.
• If wire and connection are OK, intermittent trou-
YES
ble or faulty ECM.
• Recheck each terminal and wire harness for
open circuit and poor connection.
NO
Replace the ECT sensor with a new one.
Engine Coolant Temp
20 °C (68 °F)
40 °C (104 °F)
80 °C (176 °F)
100 °C (212 °F)
Resistance
Approx. 2.58 kΩ
Approx. 1.14 kΩ
Approx. 0.28 kΩ
Approx. 0.155 kΩ
2
ECM Coupler

Advertisement