On-Board System Readiness Tests Access Procedure; Pid/Data Monitor And Record Procedure - Mazda CX-7 2007 Workshop Manual

2007 mazda cx-7
Hide thumbs Also See for CX-7 2007:
Table of Contents

Advertisement

On-Board System Readiness Tests Access Procedure

1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following
items from the initial screen of the M-MDS.
• When using the IDS (notebook PC)
1. Select the "Toolbox" tab.
2. Select "Powertrain".
3. Select "OBD Test Modes".
4. Select "Mode 1 Powertrain Data".
• When using the PDS (pocket PC)
1. Select "OBD II Modes".
2. Select "Mode 1 Powertrain Data".
3. Then, select the "***SUP" and "***EVAL" PIDs in
the PID selection screen.
4. Monitor those PIDs and check it system monitor is
completed.

PID/DATA Monitor and Record Procedure

Note
• The PID/DATA MONITOR function monitors the calculated value of the input/output signals in the PCM.
Therefore, an output device malfunction is not directly indicated as a malfunction of the monitored value
for the output device. If a monitored value of an output device is out of specification, inspect the monitored
value of the input device related to the output control.
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following
items from the initial screen of the M-MDS.
• When using the IDS (notebook PC)
1. Select the "Toolbox" tab.
2. Select "DataLogger".
3. Select "Module".
4. Select "PCM".
• When using the PDS (pocket PC)
1. Select "Module Tests".
2. Select "PCM".
3. Select "DataLogger".
3. Select the PID from the PID table.
4. Verify the PID data according to the directions on
the screen.
Diagnostic Monitoring Test Results Access Procedure
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following
items from the initial screen of the M-MDS.
• When using the IDS (notebook PC)
1. Select the "Toolbox" tab.
2. Select "Powertrain".
3. Select "OBD Test Modes".
4. Select "Mode 6 On-Board Test Results".
• When using the PDS (pocket PC)
1. Select "OBD II Modes".
2. Select "Mode 6 On-Board Test Results".
3. Verify the diagnostic monitoring test result
according to the directions on the screen.
01-02–8
ON-BOARD DIAGNOSTIC [L3 WITH TC]
DLC-2
DLC-2
DLC-2
acxuuw00001891
acxuuw00001891
acxuuw00001891

Hide quick links:

Advertisement

Table of Contents
loading