Wastegate Control Solenoid Valve Installation Note
1. Install the wastegate control solenoid valve.
Tightening torque
7.8— 10.8 N·m {80— 110 kgf·cm, 70— 95 in·lbf}
WASTEGATE
CONTROL
SOLENOID
VALVE
2. Install the hose as shown in the figure.
Throttle Body Installation Note
1. Tighten the throttle body installation bolts in the
order shown in the figure.
Tightening torque
8— 11.5 N·m {82— 117 kgf·cm, 71— 101
in·lbf}
Air Cleaner Case Installation Note
Caution
• Before assembling the air cleaner, verify that the rubber mounts have not fallen off from the air
cleaner bracket (3 locations).
• Always install the air cleaner case using the following procedure.
Note
• When inserting the rubber mounts into the air cleaner case, soapy water can be applied.
1. Verify that the rubber mounts are set in the air cleaner bracket (3 locations).
2. Install the projections on the frame side (2 locations).
3. Verify that the projections on the frame side are installed securely.
4. Install the projection on the engine side (remaining location).
5. Verify that the projection on the engine side installed securely.
01-13–10
INTAKE-AIR SYSTEM [L3 WITH TC]
A
7.8—10.8 N·m
{80—110 kgf·cm,
70—95 in·lbf}
1—3 mm
{0.04—0.11 in}
(36˚)
DETAIL A
B
1—4 mm
{0.04—0.15 in}
DETAIL B
!
(95˚)
(190˚)
acxuuw00000211
729)4,
acxuuw00000284