Installation and Configuration

User Lines Cable Connection

To Connector
on XFR

Figure 2-7 User Lines Cable with Ferrite Block

2–28
Use a standard 8-position telephone jack and data cable to connect to the
user line connector. Add a ferrite block to reduce radiated emission. The
one inch square ferrite block with built-in housing clip is packaged and
shipped with the power supply interface card.
To install the ferrite block:
1. Position the block no more than 5 cm (2 in.) from the power supply
end of the user line connector cable.
2. Open the ferrite block housing.
3. Loop the cable through the ferrite block. See
Cable with Ferrite Block" on page
4. Close the housing clip.
The ferrite block ensures that the power supply system meets radiated
emission requirement 89/336/EEC for CE mark approval. See the power
supply's operating manual for noise specifications.
Ferrite Block
Figure 2-7, "User Lines
2–28.
User Lines Cable
To User Custom Interface
TM-XR9B-01XN