Set V, I, And P Limits; Triggered Setpoints - Xantrex GPIB-M-HPD Operating Manual

Multichannel functionality for programmable dc power supplies
Table of Contents

Advertisement

Set V, I, and P
The voltage, current and power setpoints can be limited to less than the supply rating
range to match the tolerance of connected equipment or any other criteria you may
Limits
have.
Once the limits have been changed from the supply's default rated output, settings
outside this range are no longer accepted.
Note Setpoint limits do not apply to the triggered outputs and auto sequence outputs.
To set the voltage limits:
SOUR:VOLT:LIM:HIGH <voltage>
SOUR:VOLT:LIM:LOW <voltage>
To set the current limits:
SOUR:CURR:LIM:HIGH <current>
SOUR:CURR:LIM:LOW <current>
If the high end of the range was set to 5 volts, the command, SOUR:VOLT 10 would
return an error.
Triggered
To set a triggered setpoint:
Setpoints
SOUR:VOLT:TRIG <voltage>
SOUR:CURR:TRIG <current>
See
Release 2.1
"Triggering Commands" on page 66
for more information.
Operation
Auto Sequencing
65