Status information includes error type and master read/write status. DCPO_ESRO field and
DCPO_PLBBEAR or DCPO_MEMBEAR lock status is also reported.
DETO
. FLO
DET1
FL1
DET2
FL2
DET3
FL3
RWO
ALO
RW1
AL1
RW2
AL2
RW3
AL3
Figure 14-8. Decompression Controller Error Status Register 0 (DCPO_ESR)
0:2
DETO
Decompression Error Type for Master 0
Master 0 is the processor core instruction
000 Time-out during ITE fetch
cache unit (ICU).
001 Time-out during block fetch
010 Memory controller error during ITE
fetch
011 Memory controller error during block
fetch
100-111 Reserved
3
RWO
ReadlWrite Status for Master
°
This implementation only reports errors for
°
Error operation was a write
compressed reads.
1 Error operation was a read
4
FLO
DCPO_ESR Field Lock for Master 0
DCPO_ESR register fields are locked when
°
DCPO_ESR fields are unlocked
the PLB_lockErr signal was active in the
1 DCPO_ESR fields are locked
cycle in which the error occurred.
5
ALO
DCPO_MEMBEARlDCPO_PLBBEAR
DCPO_MEMBEAR and DCPO_PLBBEAR
Address Lock for Master 0
are locked to this master address when the
o
Master has not locked
PLB_lockErr signal was active in the cycle
DCPO_MEMBEAR and
in which the error occurred.
DCPO_PLBBEAR
1 Master has locked DCPO_MEMBEAR
and DCPO_PLBBEAR
6:8
DET1
Decompression Error Type for Master 1
See description for DCPO_ESR[DETO].
Master1 is the processor core data cache
unit (DCU).
9
RW1
ReadlWrite Status for Master 1
This implementation only reports errors for
o
Error operation was a write
compressed reads.
1 Error operation was a read
10
FL1
DCPO_ESR Field Lock for Master 1
DCPO_ESR register fields are locked when
o
DCPO_ESR fields are unlocked
the PLB_lockErr signal was active in the
1 DCPO_ESR fields are locked
cycle in which the error occurred.
11
AL1
DCPO_MEMBEAR/DCPO_PLBBEAR
DCPO_MEMBEAR and DCPO_PLBBEAR
Address Lock for Master 1
are locked to this master address when the
o
Master has not locked
PLB_lockErr signal was active in the cycle
DCPO_MEMBEAR and
in which the error occurred.
DCPO_PLBBEAR
1 Master has locked DCPO MEMBEAR
-
and DCPO_PLBBEAR