IBM 4767 Installation Manual

IBM 4767 Installation Manual

Pcie cryptographic coprocessor

Advertisement

Quick Links

IBM
4767 PCIe Cryptographic Coprocessor
Installation Manual

Advertisement

Table of Contents
loading

Summary of Contents for IBM 4767

  • Page 1 4767 PCIe Cryptographic Coprocessor Installation Manual...
  • Page 2 Before using this information and the product it supports, read the information in “Safety and environmental notices” on page ix and in “Notices” on page 13. Also read IBM Systems Environmental Notices and User Guide, Z125-5823, and IBM Systems Safety Notices, G229-9054.
  • Page 3: Table Of Contents

    Glossary ....19 Batteries . Requirements and specifications . Index ....21 Hardware requirement . Software requirement © Copyright IBM Corp. 2016...
  • Page 4 4767 PCIe Installation...
  • Page 5: Figures

    Figures Jumpers on the IBM 4767-002 PCIe Battery holder . Cryptographic Coprocessor (front side). © Copyright IBM Corp. 2016...
  • Page 6 4767 PCIe Installation...
  • Page 7: Tables

    Tables Danger Notices Jumpers on the IBM 4767-002 PCIe Caution Notices Cryptographic Coprocessor Operating, storage, and shipping environmental Part numbers for battery-replacement kits specifications . © Copyright IBM Corp. 2016...
  • Page 8 4767 PCIe Installation...
  • Page 9: Safety And Environmental Notices

    Safety notices For safety information in your national language, refer to the IBM Systems Safety Notices, G229-9054, included in the publications package shipped with the product. Safety notices may be printed throughout this guide. DANGER notices warn you of conditions or procedures that can result in death or severe personal injury.
  • Page 10: Danger Notices

    Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied a power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 11: World Trade Safety Information

    This unit must be recycled or discarded according to applicable local and national regulations. IBM encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. IBM offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products.
  • Page 12: Battery Return Program

    In the United States, IBM has established a return process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333.
  • Page 13 Please recycle batteries For the European Union: Notice: This mark applies only to countries within the European Union (EU) and Norway. Batteries or packaging for batteries are labeled in accordance with European Directive 2006/66/EC concerning batteries and accumulators and waste batteries and accumulators.
  • Page 14 The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5 Chapter 33. Best Management Practices for Perchlorate Materials. This product, part or both may include a lithium manganese dioxide battery which contains a perchlorate substance. 4767 PCIe Installation...
  • Page 15: About This Document

    Before installing a coprocessor, check the Approved x86 servers list on the IBM product website for the approved server list: http://www.ibm.com/security/cryptocards Click on the HSM 4767 link in the left sidebar, then click on the Approved x86 servers link in the left sidebar. © Copyright IBM Corp. 2016...
  • Page 16 4767 PCIe Installation...
  • Page 17: Chapter 1. Introduction

    IBM-approved x86 servers. Refer to “Where to find more information” on page xv. You can install the coprocessor, a standard height, half-length PCIe adapter card, only in an IBM-approved x86 server. Refer to “Where to find more information” on page xv.
  • Page 18: Storage

    Hardware requirement The coprocessor must be installed in a select x86 server from the list of IBM-approved x86 servers. See notes below. No additional hardware or cabling is required. Notes: 1. The full speed USB 2.0 Type A connector is for development use only. It is not intended for customer use.
  • Page 19: Environmental Specifications

    Environmental specifications The environmental specifications for the IBM 4767-002 PCIe Cryptographic Coprocessor are shown in Table 3. Table 3. Operating, storage, and shipping environmental specifications Operating Shipping environment Storage environment environment Temperature +10°C - +35°C +1°C - +60°C -34°C - +60°C (+50°F - +95°F)
  • Page 20 4767 PCIe Installation...
  • Page 21: Chapter 2. Installing The Coprocessor

    Chapter 2. Installing the coprocessor This section describes installing the IBM 4767-002 PCIe Cryptographic Coprocessor. About this task Note that it is not necessary to install the support software before installing a coprocessor. To install the coprocessor into the host computer, follow these steps: Procedure 1.
  • Page 22: Jumpers On The Ibm 4767-002 Pcie

    Figure 1. Jumpers on the IBM 4767-002 PCIe Cryptographic Coprocessor (front side) Table 4. Jumpers on the IBM 4767-002 PCIe Cryptographic Coprocessor Jumper Number of PINS Name of jumper Position when shipped Battery holder Shipped with two batteries installed. USB Standard-A (Type A) connector...
  • Page 23: Chapter 3. Replacing Coprocessor Batteries

    This section describes the way to replace the batteries on the coprocessor. Before you begin Two lithium batteries mounted on the IBM 4767-002 PCIe Cryptographic Coprocessor supply power to the card’s components, including protected memory. Your support software or application software can query the coprocessor to determine whether the batteries need to be replaced.
  • Page 24 14. Refer to Figure 2 on page 9. Install the fresh and tested battery (not the one in the temporary-battery tray) with the flat end of the battery (+) positioned at the outside end of the top socket of the battery holder, and the button end of 4767 PCIe Installation...
  • Page 25 the battery (-) positioned at the middle of the battery holder. This newly installed battery provides sufficient power to the coprocessor. Figure 2. Battery holder 15. Unplug the battery tray from the P1 connector. Remove the battery from the tray for use in the next step. 16.
  • Page 26 4767 PCIe Installation...
  • Page 27: Chapter 4. Transporting A Coprocessor

    Chapter 4. Transporting a coprocessor This section provides guidelines to follow when it becomes necessary to travel with or ship an IBM 4767-002 PCIe Cryptographic Coprocessor. This chapter addresses protecting the coprocessor from physical damage. It also touches on some export and import considerations. This chapter does not attempt to address issues with data security.
  • Page 28: Traveling Internationally With A Coprocessor

    These materials include a cardboard box, pieces of foam, bags of isothermal gel, a bag containing a dessicant, and an electrostatic discharge barrier bag. Before using the bags of isothermal gel, keep them at room temperature for a reasonable amount of time. 4767 PCIe Installation...
  • Page 29: Notices

    Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.
  • Page 30: Trademarks

    IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee.
  • Page 31 Consult an IBM-authorized dealer or service representative for help. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM authorized dealers. IBM is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment.
  • Page 32 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung von IBM gesteckt/eingebaut werden.
  • Page 33 Tel: 914-499-1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Regulations, Abteilung M372 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 (0) 800 225 5423 or +49 (0) 180 331 3233 email: halloibm@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse B.
  • Page 34 4767 PCIe Installation...
  • Page 35: Glossary

    Glossary This glossary includes some terms and definitions from the IBM Dictionary of Computing, New York: McGraw Hill, 1994. This glossary also includes some terms and definitions from: v The American National Standard Dictionary for Information Systems, ANSI X3.172-1990, copyright 1990 by the American National Standards Institute (ANSI).
  • Page 36 One of several receptacles available inside a computer, into which a user can install an expansion card. feature Part of an IBM product able to be ordered separately. Federal Communications Commission (FCC) A board of commissioners, appointed by the President under the...
  • Page 37: Index

    3 specifications 2 world trade safety xi storage 1 storage requirements 2 support program 2 tamper sensors 1 installing coprocessor 5 temperature 2 X-ray tamper 11 travel guidelines 11 © Copyright IBM Corp. 2016...