The <num> parameter is a loopback interface or virtual interface number. If you specify an Ethernet port, the
<portnum> is the port's number (including the slot number, if you are configuring an HP 9304M or HP 9308M.
To specify the first IP address configured on a loopback interface as the device's SNMP trap source, enter
commands such as the following:
HP9300(config)# int loopback 1
HP9300(config-lbif-1)# ip address 10.0.0.1/24
HP9300(config-lbif-1)# exit
HP9300(config)# snmp-server trap-source loopback 1
The commands in this example configure loopback interface 1, assign IP address 10.00.1/24 to the loopback
interface, then designate the interface as the SNMP trap source for this routing switch. Regardless of the port the
HP device uses to send traps to the receiver, the traps always arrive from the same source IP address.
The following commands configure an IP interface on an Ethernet port and designate the address as the SNMP
trap source for a routing switch. The HP device always sends traps through the Ethernet port and the source IP
address of the traps is always the first IP address configured on the Ethernet port.
HP9300(config)# interface eth 2/1
HP9300(config-if-2/1)# ip address 209.157.22.26/24
HP9300(config-if-2/1)# exit
HP9300(config)# snmp trap-source eth 2/1
USING THE WEB MANAGEMENT INTERFACE
You cannot configure a trap source using the Web management interface.
Disabling SNMP Traps
HP switches and routing switches come with SNMP trap generation enabled by default for all traps. You can
selectively disable one or more of the following traps.
NOTE: By default, all SNMP traps are enabled at system startup.
Switch Traps
The following traps are generated on the switches:
SNMP authentication keys
Power supply failure
Fan failure
Cold start
Link up
Link down
Bridge new root
Bridge topology change
Locked address violation
Module insert (applies only to Chassis devices)
Module remove (applies only to Chassis devices)
Routing Switch Traps
The following traps are generated on the routing switches:
SNMP authentication key
Power supply failure
Fan failure
Configuring Basic Features
9 - 7