FF1: System Programming
Introduction

FF1 0 21: Ring Alarm for Unanswered Calls

0
System
Configuration
Ring Alarm Frequency
(all CPCs) - Version 1.0 or higher
Set the ringing frequency that will begin after an incoming call rings unanswered for
FF1
longer than the Slide Ring/Alarm Ring Timer.
System
FF2
Trunks
FF3
Extensions
Notes:
FF4
FF-/Soft Keys
Alarm Ringing: Ringing frequency/interval changes for an incoming call that rings unanswered for
longer than the Slide Ring/Alarm Ring Timer.
Alarm Ringing will not work while Slide Ringing or Delayed Ringing is occurring.
FF5
Groups
Related Programming:
Slide Ring/Alarm Ring Timer (Day1) (pg. 1-132)
Slide Ring/Alarm Ring Timer (Day2) (pg. 1-133)
FF6
Slide Ring/Alarm Ring Timer (Night) (pg. 1-133)
TRS/ARS
Alarm Ringing (pg. 2-24) (for analog CO trunks)
Alarm Ringing (pg. 2-68) (for ISDN trunks)
Alarm Ringing (pg. 2-102) (for T1 CO trunks)
FF7
Applications
FF8
Maintenance
Appendix A
Appendix B
Page 1-106
FF1 0 21 0001 Hold (0-6) Hold
FF2 1 BSSC 03 06 Hold (0 or 1) Hold
DBS 576 (USA) issued 05/20/98
0=no ring
1=400/562 Hz (default)
2=1000/1340 Hz
3=400 Hz
4=800/1040 Hz
5=1040/1320 Hz
6=660/1320 Hz
FF1 1 02 0007 Hold (0-255) Hold
FF1 1 02 0008 Hold (0-255) Hold
FF1 1 02 0009 Hold (0-255) Hold
FF2 0 BSSC 02 13 Hold (0 or 1) Hold
FF2 2 BSSCC 03 11 Hold (0 or 1) Hold
Section 400-Programming
 /52 "*D
576-13-400
Introduction
0
System
Configuration
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
FF7
Applications
FF8
Maintenance
Appendix A
Appendix B

Advertisement

Table of Contents
loading

Table of Contents