Ff1 2: Dial Plan; Table 1-5. Maximum/Minimum Dialing At Intercom Dial Tone (Ff1 2 01) - Panasonic DBS-576 Technical Manual

Section 400 programming
Hide thumbs Also See for DBS-576:
Table of Contents

Advertisement

FF1: System Programming
1.
Introduction

FF1 2: Dial Plan

0
System
1.
Maximum/Minimum Dialing at Intercom Dial Tone
Configuration
(all CPCs) - Version 1.0 or higher
Set the maximum and minimum number of digits that can be dialed by the end-user
FF1
during intercom dial tone. This applies to both Dial Plans A and B.
System
FF2
0001=Maximum length of dialed-digit strings beginning with "1"
Trunks
0002=Minimum length of dialed-digit strings beginning with "1"
0003=Maximum length of dialed-digit strings beginning with "2"
0004=Minimum length of dialed-digit strings beginning with "2"
FF3
0005=Maximum length of dialed-digit strings beginning with "3"
...
Extensions
0024=Minimum length of dialed-digit strings beginning with "#"
Notes:
FF4
If the number of dialed digits is shorter than the String Length set in this address, the call attempt will be
FF-/Soft Keys
treated as misdialing after the Interdigit Timer expires.
Related Programming:
FF5
Dial Plan Assignment (pg. 3-27) for digital keyphones/SLTs
Groups
Dial Plan Assignment (pg. 3-39) for S-point ISDN extensions
Interdigit Timer (DP SLTs) (pg. 1-141)
Interdigit Timer (DTMF SLTs) (pg. 1-142)
Interdigit Timer (Digital Keyphones) (pg. 1-142)
FF6
TRS/ARS

Table 1-5. Maximum/Minimum Dialing at Intercom Dial Tone (FF1 2 01)

FF7
Applications
FF8
Maintenance
Appendix A
Appendix B
Page 1-154
FF1 2 01 (0001-0024) Hold (1-4) Hold
Maximum Digit Length
First Digit Dialed...
Address No.
1
0001
2
0003
3
0005
4
0007
5
0009
6
0011
7
0013
8
0015
9
0017
0
0019
0021
#
0023
DBS 576 (USA) issued 05/20/98
FF3 0 BSSC 09 Hold (1 or 2) Hold
FF3 1 BSSC 08 Hold (1 or 2) Hold
FF1 1 03 0006 Hold (0-255) Hold
FF1 1 03 0007 Hold (0-255) Hold
FF1 1 03 0008 Hold (0-255) Hold
Default
Address No.
4
4
4
4
4
4
3
2
1
1
3
2
Section 400-Programming
,  2+
String Length (1-4 digits)
(see table below for defaults)
Minimum Digit Length
Default
0002
2
0004
2
0006
2
0008
2
0010
2
0012
2
0014
3
0016
2
0018
1
0020
1
0022
2
0024
1
Introduction
0
System

Configuration
FF1
System
FF2
Trunks
FF3
Extensions
FF4
FF-/Soft Keys
FF5
Groups
FF6
TRS/ARS
FF7
Applications
FF8
Maintenance
Appendix A
Appendix B
576-13-400

Advertisement

Table of Contents
loading