SIP User's Manual
Second Signal Off Time [10 msec]:
second cadence on-off cycle. Can be omitted if there isn't a second cadence.
Third Signal On Time [10 msec]:
third cadence ON-OFF cycle. Can be omitted if there isn't a third cadence.
Third Signal Off Time [10 msec]:
third cadence ON-OFF cycle. Can be omitted if there isn't a third cadence.
Fourth Signal On Time [10 msec]:
fourth cadence ON-OFF cycle. Can be omitted if there isn't a fourth cadence.
Fourth Signal Off Time [10 msec]:
fourth cadence ON-OFF cycle. Can be omitted if there isn't a fourth cadence.
Carrier Freq [Hz]:
Modulation Freq [Hz]:
range from 1 to 128 Hz).
Signal Level [-dBm]:
AM Factor [steps of 0.02]: amplitude modulation factor (valid range from 1 to 50.
Recommended values from 10 to 25).
Notes:
For example, to configure the dial tone to 440 Hz only, enter the following text:
#Dial tone
[CALL PROGRESS TONE #1]
Tone Type=1
Tone Form =1 (continuous)
Low Freq [Hz]=440
High Freq [Hz]=0
Low Freq Level [-dBm]=10 (-10 dBm)
High Freq Level [-dBm]=32 (use 32 only if a single tone is
required)
First Signal On Time [10msec]=300; the dial tone is detected after
3 sec
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=0
Second Signal Off Time [10msec]=0
Version 5.8
frequency of the carrier signal for AM tones.
frequency of the modulated signal for AM tones (valid
level of the tone for AM tones.
When the same frequency is used for a continuous tone and a cadence
tone, the 'Signal On Time' parameter of the continuous tone must have a
value that is greater than the 'Signal On Time' parameter of the cadence
tone. Otherwise the continuous tone is detected instead of the cadence
tone.
The tones frequency should differ by at least 40 Hz from one tone to
other defined tones.
'Signal Off' period (in 10 msec units) for the
'Signal On' period (in 10 msec units) for the
'Signal Off' period (in 10 msec units) for the
'Signal On' period (in 10 msec units) for the
'Signal Off' period (in 10 msec units) for the
393