AudioCodes Mediant 2000 User Manual page 328

Media gateway
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

Parameter
Web: Digital Out-Of-Service
Behavior
EMS: Digital OOS Behavior For
Trunk Value
[DigitalOOSBehaviorFor
Trunk_ID]
Web: Digital Out-Of-Service
Behavior
[DigitalOOSBehavior]
SIP User's Manual
LocalISDNRBSource is set to 1.
Determines the method for setting digital trunks to Out-Of-
Service state per trunk.
[-1]
Not Configured = Use the settings of the
DigitalOOSBehavior parameter for per device (default).
[0]
Default = Uses default behavior for each trunk (see
note below).
[1]
Service = Sends ISDN In or Out of Service (only for
ISDN protocols that support Service message).
[2]
D-Channel = Takes D-Channel down or up (ISDN only).
[3]
Alarm = Sends or clears PSTN AIS Alarm (ISDN and
CAS).
[4] Block = Blocks trunk (CAS only).
Notes:
This parameter is applicable only if the parameter
EnableBusyOut is set to 1.
The default behavior (value 0) is as follows:
ISDN:
Use Service messages on supporting variants
and use Alarm on non-supporting variants.
CAS:
Use Alarm.
When updating this parameter value at run-time, you must
stop the trunk and then restart it for the update to take
effect.
To determine the method for setting Out-Of-Service state
for all trunks (i.e., per device), use the DigitalOOSBehavior
parameter.
The ID in the ini
file parameter name represents the trunk
number, where 0 is the first trunk.
Determines the method for setting digital trunks to Out-Of-
Service state per device.
[0]
Default = Uses default behavior for each trunk - see
note below (default)
[1]
Service = Sends ISDN In or Out of Service (only for
ISDN protocols that support Service message).
[2]
D-Channel = Takes D-Channel down or up (ISDN only).
[3]
Alarm = Sends or clears PSTN AIS Alarm (ISDN and
CAS).
[4] Block = Blocks trunk (CAS only).
Notes:
This parameter is applicable only if the parameter
EnableBusyOut is set to 1.
The default behavior (value 0) is as follows:
ISDN:
Use Service messages on supporting variants
and use Alarm on non-supporting variants.
CAS:
Use Alarm.
When updating this parameter value at run-time, you must
stop the trunk and then restart it for the update to take
effect.
328
Description
Document #: LTRT-68809
Mediant 2000

Advertisement

Table of Contents
loading

Table of Contents