1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419
Effect Guide

167: Hold Delay

This effect records the input signal and plays it back
repeatedly. You can control the start of recording and reset
via a modulation source. Easy to use for real-time
performances.
Wet: Mono In - Stereo Out / Dry: Stereo In - Stereo Out
Left
+
Right
D
-mod
REC Control
D
-mod
RST Control
Loop Time
Auto,
a
[msec]
1...10800
b Loop BPM
Off, On
Sync
MIDI,
BPM
40.00...
300.00
c
Time Over?
---, OVER!
Loop Base
...
Note
d
Times
x1...x32
e REC Control
Off...Tempo
Src
RST Control
f
Off...Tempo
Src
Manual REC
REC Off,
g
Control
REC On
Manual RST
h
Off, RESET
Control
L100...L1, C,
Pan
R1...R100
i
Src
Off...Tempo
Amt
–100...+100
Dry, 1 : 99...
Wet/Dry
99 : 1, Wet
j
Src
Off...Tempo
Amt
–100...+100
a: Loop Time [msec]
With Auto, the loop time is automatically set. Otherwise,
you can specify the loop time.
When Auto is selected, the Loop Time is automatically set to
the time it takes for a performance recorded while the
Modulation Source or Manual REC Control is on. However,
if the time length exceeds 10,800msec, the loop time will be
automatically set to 10,800msec.
c: Time Over?
You can set the delay time up to 10,800msec. If the delay
time exceeds this limit, the error message "OVER!" appears
in the display. Set the delay time parameters so that this
message will not appear. Time Over? is only a display
parameter.
370
Delay
Pan
Loop Time: Auto/ ...5400ms
Tempo
BPM
Base Note x Times
BPM
Sets Automatic loop time setup
mode or specifies loop time
p.370
Specifies whether delay time is
set in milliseconds, or as a note
value relative to tempo
p.370
MIDI syncs to the system
tempo; 40–300 sets the tempo
manually for this individual
effect
p.370
An error indication that appears
if delay time exceeds the upper
limit when MIDI/Tempo
Sync=On
Selects the type of notes to
specify the delay time
p.370
Sets the number of notes to
specify the delay time
p.370
Selects control source for
recording
p.370
Selects control source for reset
p.370
Sets the recording switch
p.370
Sets the reset switch
p.370
Sets the stereo image of the
effect
Selects the modulation source
of stereo image of the effect
Sets the modulation amount of
stereo image of the effect
Sets the balance between the
effect and the dry input
Selects a modulation source for
Wet/Dry
Sets the modulation amount
for Wet/Dry
b: Loop BPM Sync
c: BPM
d: Loop Base Note
d: Times
If Loop BPM Sync is on, the Times setting is ignored; the
loop time is determined by BPM, Loop Base Note, and
Times. Even in this case, the delay time cannot exceed
10,800 msec.
"Hold" procedure (when Loop Time = Auto)
Wet / Dry
1. "Rec Src" JS +Y: #01
"Reset Src" JS –Y: #02
"Manual REC Control" REC Off
"Manual RST Control" RESET
"Loop Time [msec]" Auto
"MIDI/Tempo Sync" Off
Wet / Dry
It should be noted that all recordings will be deleted
while Reset is On.
2. "Manual RST Control" Off
Reset is cancelled and the unit enters Rec ready mode.
3. Push the joystick in the +Y direction (forward) and play a
phrase you wish to hold. When you pull the joystick to
its original position, the recording will be finished and
the phrase you just played will be held.
Loop Time is automatically set only for the first recording
after resetting. If the time length exceeds 10,800msec,
Loop Time will be automatically set to 10,800msec. (If
you have set Times to 1–10,800msec, the specified loop
time will be used regardless of the time taken from push-
ing the joystick forward until it is pulled back. However,
the recording method remains the same. The phrase
being played while the joystick is pushed forward will be
held.)
4. If you made a mistake during recording, pull the joystick
in the –Y direction (back) to reset. In this way, the
recording will be erased. Repeat step 3. again.
5. The recorded phrase will be repeated again and again.
You can use this to create an accompaniment.
6. By pushing the joystick in the +Y direction (forward),
you can also overdub performances over the phrase that
is being held.
e: REC Control Src
g: Manual REC Control
REC Control Src selects the modulation source that controls
recording.
If this modulation is on, or if Manual REC Control is set to
On, you can record the input signal. If a recording has
already been carried out, additional signals will be
overdubbed.
The effect is off when a value for the modulation source
specified for the REC Control Src parameter is 63 or
smaller, and the effect is on when the value is 64 or
higher.
f: RST Control Src
h: Manual RST Control
The RST Control Src parameter specifies the modulation
source that controls the reset operation.
When you set this modulation source to On, or Manual RST
Control to RESET, you can erase what you recorded. If the
Loop Time parameter has been set to Auto, the loop time is
also reset.
The effect is off when a value for the modulation source
specified for the RST Control Src parameter is 63 or
smaller, and the effect is on when the value is 64 or
higher.