Korg M50-88 Parameter Manual page 299

M50 series music workstation
Table of Contents

Advertisement

Side PEQ
Sets the EQ center frequency
20...12.00k
Cutoff [Hz]
for the trigger signal
Sets the EQ bandwidth for the
h
Q
0.5...10.0
trigger signal
Sets the EQ gain for the trigger
Gain [dB]
–18.0...+18.0
signal
Dry, 1 : 99...
Sets the balance between the
Wet/Dry
99 : 1, Wet
effect and the dry input
Selects a modulation source for
i
Src
Off...Tempo
Wet/Dry
Sets the modulation amount
Amt
–100...+100
for Wet/Dry
a: Envelope Source
By selecting FX Control 1 or FX Control 2 you can use the
signal of FX Control Bus 1 or 2 as the trigger signal.
For instance, you might use a different, unprocessed sound
as the trigger, or apply a limiter triggered by a different
timbre (Combination) or track (Sequence). For more
information, please see "FX Control Buses" on page 274.
b: Envelope Select
When L/R Mix is selected for this parameter, the left and
right channels are linked to control the Limiter using the
mixed signal. If L Only (or R Only) is selected, the left and
right channels are linked, and the Limiter is controlled via
only the left (or right) channel.
With L/R individually, the left and right channels control
the Limiter individually.
c: Ratio
d: Threshold [dB]
f: Gain Adjust [dB]
This parameter sets the signal compression Ratio.
Compression is applied only when the signal level exceeds
the Threshold value.
Adjust the output level using the Gain Adjust parameter,
since compression causes the entire level to be reduced.
Output Level
Threshold
Louder
Ratio=1.0 : 1
Dry
Level
Ratio=2.0 : 1
Ratio=4.0 : 1
Ratio=Inf : 1
e: Attack
e: Release
These parameters set the attack time and release time. A
higher attack time will cause the compression to be applied
more slowly.
p.291
p.291
p.291
Limiter - Threshold / Ratio
Ratio=1.0 : 1
Ratio=2.0 : 1
Ratio=4.0 : 1
Ration=Inf : 1
Input Level
Threshold
Time
Dry
Wet
Wet
Attack
g: Trigger Monitor
Setting this parameter On will cause the trigger signal to be
output, instead of the effect sound. Use this parameter to
check the trigger signal with EQ applied.
Usually, set this to Off.
g: Side PEQ Insert
h: Side PEQ Cutoff [Hz]
h: Q
h: Gain [dB]
These parameters are used to set the EQ applied to the
trigger signal.
The Limiter determines whether the compression is applied
or not, based on the post-EQ trigger signal. Setting the
equalizer allows you to set the Limiter to respond to any
frequency band.
Dynamics (Dynamic)
Limiter - Attack / Release
Threshold
Ratio=Inf : 1
Attack=1
Release=1
Ratio=Inf : 1
Attack=100
Release=100
Release
291

Advertisement

Table of Contents
loading

This manual is also suitable for:

M50-73M50-61

Table of Contents