View Port Status - ZyXEL Communications ENC User Manual

Enterprise network center
Table of Contents

Advertisement

Chapter 8 Application
Table 100 Port Management > Basic Setting (continued)
LABEL
Loop Guard
Active
PD Power
Status
Class
PD Priority
Apply
Reset

8.4.2 View Port Status

Use this screen to view the port statistics.
To open this screen, select an entry and click View Status in the Application > Port
Management > Basic Setting screen.
Figure 167 Port Management > Basic Setting > View Status
The following table describes the labels in this screen.
Table 101 Port Management > Basic Setting > View Status
LABEL
Port
Link
State
PD
218
DESCRIPTION
Select Loop Guard Active to enable loop guard on the port. You have to globally enable
loop guard by selecting the Active Loop Guard field before you enable it on the port.
This field is only available for ZyXEL's Ethernet Switch PWR models. Select the check box to
enable PoE (Power over Ethernet) on this port. Clear the check box to disable it on the port.
This field is only available for ZyXEL's Ethernet Switch PWR models. This field displays the
DSCP (DiffServ Code Point) number (between 0 and 63) for the port.
This field is only available for ZyXEL's Ethernet Switch PWR models.
When the total power requested exceeds the total PoE power budget the PoE device can
provide, you can set the priority level to have the PoE device supplies power according to
different priority levels. The priority from high to low is Critical > High > Low.
Select Critical if the traffic flow through the port is very sensitive to jitter (for example,
voice traffic).
Select High if the traffic flow through the port is important but non-critical. The PoE device
supplies power to the ports only after all critical-priority ports are served.
Select Low if the traffic flow through this port is non-critical and can tolerate some delay.
The PoE device supplies power to the ports only after all high-priority ports are served.
Click Apply to save your changes.
Click Reset to discard your changes and reset the fields to their last saved settings.
DESCRIPTION
This identifies the Ethernet port.
This field displays the speed (either 10M for 10Mbps, 100M for 100Mbps or another value
depending on the uplink module being used). Down displays if the port is disconnected.
If STP (Spanning Tree Protocol) is enabled, this field displays the STP state of the port (see
Section 8.4.2.1 on page 219
If STP is disabled, this field displays Forwarding if the link is up, otherwise, it displays STOP.
This field shows if PoE (Power over Ethernet) is on or off on this port. This field only shows for
ZyXEL's Ethernet Switch PWR models.