ZyXEL Communications ENC User Manual page 205

Enterprise network center
Table of Contents

Advertisement

The following table describes the labels in this screen.
Table 94 RMON > Alarm Config > New
LABEL
Port Number
Variable
Interval
Sample Type
Startup Alarm
Owner
Rising Condition
Threshold
Event Index
Falling Condition
ENC User's Guide
DESCRIPTION
Select which port or interface whose data will be sampled.
Select the type of data to be sampled:
ifInOctets - total number of octets received
ifInUcastPkts - the total number of good unicast packets received
ifInNUcastPkts - the total number of good non-unicast packets received
ifInDiscards - the total number of packets received that were dropped
ifInErrors - the total number of error packets received
ifInUnknownProtocol - the total number of packets received that were dropped because
of an unknown or unsupported protocol
ifInMulticastPkts - the total number of good multicast packets received
ifInBroadcastPkts - the total number of good broadcast packets received
ifOutOctets - total number of octets transmitted
ifOutUcastPkts - the total number of unicast packets requested to be transmitted
ifOutNUcastPkts - the total number of non-unicast packets requested to be transmitted
ifOutDiscards - the total number of outbound packets that were dropped
ifOutErrors - the total number of outbound error packets
ifOutQLen - the length of the output packet queue
ifOutMulticastPkts - the total number of multicast packets requested to be transmitted
ifOutBroadcastPkts - the total number of broadcast packets requested to be
transmitted
Specify the time between data samplings.
Select the method of obtaining the sample value.
Absolute: means the sampling value is accumulated since it started.
Delta: means the value is from the data sampled in each configured time interval.
Select the startup alarm type.
Rising Alarm: means the probe triggers an alarm when the value is greater or equal to the
rising threshold.
Falling Alarm: means the probe triggers an alarm when the value is less than or equal to
the falling threshold.
Rising & Falling Alarm: means Rising or Falling. That is, the probe triggers an alarm
when either one of the above cases occurs.
Enter a descriptive name of the application that creates this entry. You can use 1-31
printable ASCII characters. Spaces are allowed.
Specify a rising threshold (between 0 and 2147483647). When a value is greater or equal
to this threshold, the probe triggers an alarm.
Select an index number of a rising event.
Chapter 8 Application
205

Advertisement

Table of Contents
loading

Table of Contents