Copying software images between active and standby management modules
To copy the monitor image from flash memory of the active management module to flash memory
of the standby module, enter the following command.
BigIron RX# copy flash flash monitor standby
Syntax: copy flash flash monitor standby
To copy the BigIron RX Series Multi-Service IronWare image from the secondary location in the
active management module's flash memory to the primary location in the active module's flash
memory, enter the following command.
BigIron RX# copy flash flash primary
Syntax: copy flash flash primary [standby]
Specify the optional standby keyword to copy the BigIron RX Series Multi-Service IronWare image
from the secondary location in the active management module's flash memory to the primary
location in the standby module's flash memory.
To copy the BigIron RX Series Multi-Service IronWare image from the primary location in the active
management module's flash memory to the secondary location in the active module's flash
memory, enter the following command.
BigIron RX# copy flash flash secondary
Syntax: copy flash flash secondary [standby]
Specify the optional standby keyword to copy the BigIron RX Series Multi-Service IronWare image
from the primary location in the active management module's flash memory to the secondary
location in the standby module's flash memory.
Copying files from a management module to an interface module
You can copy a software image or other type of file from the management module's flash memory
to the flash memory of one or all interface modules.
For example, to copy the interface module's monitor image from the management module to all
interface modules, enter a command such as the following.
BigIron RX# copy flash lp nlb02200.bin monitor all
Syntax: copy flash lp <source-file> monitor | primary | secondary <slot-number> | all
For example, to copy a file called test.cfg from the management module to the interface module in
slot 1, enter a command such as the following.
BigIron RX# copy flash lp test.cfg lptest.cfg 1
Syntax: copy flash lp <source-file> <dest-file> <slot-number> | all
Copying BigIron RX Series Multi-Service IronWare images from flash memory to a
TFTP server
You can copy the management module's BigIron RX Series Multi-Service IronWare images from the
primary and secondary locations in flash memory to a TFTP server.
For example, to copy the BigIron RX Series Multi-Service IronWare image in the secondary location
in flash memory to a TFTP server, enter a command such as the following.
BigIron RX Series Configuration Guide